Sensitive Routine Liquid Chromatography-Tandem Mass Spectrometry Method for Serum Estradiol and Estrone Without Derivatization

Steven Pauwels, Leen Antonio, Ivo Jans, Anneleen Lintermans, Patrick Neven, Frank Claessens, Brigitte Decallonne, Jaak Billen, Dirk Vanderschueren, Pieter Vermeersch

Anal Bioanal Chem. 2013 Oct;405(26):8569-77.

PMID: 23892882

Abstract:

The need for a routinely applicable assay to measure low estradiol levels in adult men, postmenopausal women, and young adolescents was recently discussed in an Endocrine Society position statement. Our aim was to develop a sensitive liquid chromatography-tandem mass spectrometry method for estradiol and estrone in human serum without the need for derivatization or extended extraction protocols. After protein precipitation of serum with a mixture of methanol/acetonitrile (85/15) (v/v) containing isotopic internal standards (17β-estradiol-16,16,17-d 3 and estrone-2,3,4-(13)C), we quantified estradiol and estrone by two-dimensional liquid chromatography-tandem mass spectrometry with electrospray ionization in the negative mode monitoring 5 × 271.20→145.00 (17β-estradiol) and 269.20→145.00 (estrone). Sensitivity was increased by using fluoride and summation of 5 identical transitions for estradiol. Our method was analytically validated, compared against direct immunoassays using serum of 25 adult men, and clinically tested by measuring samples of 3 men at baseline and after chemical castration, 30 postmenopausal women and 15 patients receiving aromatase inhibitors. Total imprecision was below 20% for the low quality controls. Limit of quantification was 1.3 ng/L (4.8 pmol/L) for estradiol and 1.2 ng/L (4.4 pmol/L) for estrone. Estradiol in Certified Reference Material BCR-576 was within specified uncertainty limits. No significant ion suppression or interference was observed. Our method showed modest correlation with direct immunoassay for estradiol (r(2) = 0.64) but no correlation for estrone (r(2) = 0.12). Patient sample results were within expected ranges. In conclusion, we developed a routinely applicable liquid chromatography-tandem mass spectrometry method for estradiol and estrone measurement which is sensitive enough for use in men, postmenopausal women, and young adolescents.

Chemicals Related in the Paper:

Catalog Number Product Name Structure CAS Number Price
AP1241684296-A Estrone-2,3,4-13C3 Estrone-2,3,4-13C3 1241684-29-6 Price
qrcode
Privacy Policy | Cookie Policy | Copyright © 2024 Alfa Chemistry. All rights reserved.