0

Construction of an Electrode Modified With gallium(III) for Voltammetric Detection of Ovalbumin

Kazuharu Sugawara, Makoto Okusawa, Yusaku Takano, Toshihiko Kadoya

Anal Sci. 2014;30(6):649-55.

PMID: 24919669

Abstract:

Electrodes modified with gallium(III) complexes were constructed to detect ovalbumin (OVA). For immobilization of a gallium(III)-nitrilotriacetate (NTA) complex, the electrode was first covered with collagen film. After the amino groups of the film had reacted with isothiocyanobenzyl-NTA, the gallium(III) was then able to combine with the NTA moieties. Another design featured an electrode cast with a gallium(III)-acetylacetonate (AA) complex. The amount of gallium(III) in the NTA complex was equivalent to one-quarter of the gallium(III) that could be utilized from an AA complex. However, the calibration curves of OVA using gallium(III)-NTA and gallium(III)-AA complexes were linear in the ranges of 7.0 × 10(-11) - 3.0 × 10(-9) M and 5.0 × 10(-10) - 8.0 × 10(-9) M, respectively. The gallium(III) on the electrode with NTA complex had high flexibility due to the existence of a spacer between the NTA and the collagen film, and, therefore, the reactivity of the gallium(III) to OVA was superior to that of the gallium(III)-AA complex with no spacer.

Chemicals Related in the Paper:

Catalog Number Product Name Structure CAS Number Price
AP14405437 Gallium(III) acetylacetonate Gallium(III) acetylacetonate 14405-43-7 Price
qrcode