0

Detection of Microbleeds Associated With Sentinel Headache Using MRI Quantitative Susceptibility Mapping: Pilot Study

Daichi Nakagawa, Kohsuke Kudo, Olatilewa Awe, Mario Zanaty, Yasunori Nagahama, Cameron Cushing, Vincent Magnotta, Minako Hayakawa, Lauren Allan, Jeremy Greenlee, Issam A Awad, Timothy Carroll, James Torner, etc.

J Neurosurg. 2018 May 1;1-7.

PMID: 29799347

Abstract:

OBJECTSentinel headaches (SHs) associated with cerebral aneurysms (CAs) could be due to microbleeds, which are considered a sign that an aneurysm is unstable. Despite the prognostic importance of these microbleeds, they remain difficult to detect using routine imaging studies. The objective of this pilot study is to detect microbleeds associated with SH using a magnetic resonance imaging (MRI) quantitative susceptibility mapping (QSM) sequence and then evaluate the morphological characteristics of unstable aneurysms with microbleeds.METHODSTwenty CAs in 16 consecutive patients with an initial presentation of headache (HA) leading to a diagnosis of CA were analyzed. Headaches in 4 of the patients (two of whom had 2 aneurysms each) met the typical definition of SH, and the other 12 patients (two of whom also had 2 aneurysms each) all had migraine HA. All patients underwent imaging with the MRI-QSM sequence. Two independent MRI experts who were blinded to the patients' clinical history performed 3D graphical analysis to evaluate for potential microbleeds associated with these CAs. Computational flow and morphometric analyses were also performed to estimate wall shear and morphological variables.RESULTSIn the 4 patients with SH, MRI-QSM results were positive for 4 aneurysms, and hence these aneurysms were considered positive for non-heme ferric iron (microbleeds). The other 16 aneurysms were negative. Among aneurysm shape indices, the undulation index was significantly higher in the QSM-positive group than in the QSM-negative group. In addition, the spatial averaged wall shear magnitude was lower in the aneurysm wall in direct contact with microbleeds.CONCLUSIONSMRI-QSM allows for objective detection of microbleeds associated with SH and therefore identification of unstable CAs. CAs with slightly greater undulation indices are associated with positive MRI-QSM results and hence with microbleeds. Studies with larger populations are needed to confirm these preliminary findings.

Chemicals Related in the Paper:

Catalog Number Product Name Structure CAS Number Price
AP110683108 ACA - CAS 110683-10-8 ACA - CAS 110683-10-8 110683-10-8 Price
qrcode