0

Electrochemical Behavior of Tectoridin and Its Sensitive Determination Based on L-arginine Modified Electrode

Wenhua Qiao, Lu Wang, Huichao Li, Gaiping Li, Jianjun Li, Baoxian Ye

Talanta. 2015 Nov 1;144:726-33.

PMID: 26452883

Abstract:

A simple, inexpensive and highly sensitive voltammetric method for the determination of tectoridin was developed using a poly(L-Arginine) modified electrode. The redox character of tectoridin at proposed electrode was studied systematically and some dynamic parameters were calculated for the first time. A reasonable reaction mechanism of tectoridin on the poly(L-Arginine)/GCE was also dicussed and proposed, which could be a reference for the pharmacological action of tectoridin in clinical study. And the electroanalytical method for determination of tectoridin was established by differential pulse voltammograms (DPV). Under optimum conditions, the response peak currents were linear relationship with tectoridin concentrations in the range of 5.0×10(-8)-2.0×10(-6) mol L(-1) with a detection limit of 4.0×10(-8) mol L(-1). Therefore, the high sensitivity for tectoridin sensing at the proposed electrode was achieved, and the proposed method could also be used to detect tectoridin in the Chinese medicinal herb Blackberrylily with satisfactory results.