Abstract:

Purpose: Reliable drug therapy with injectable intravitreal implants requires implants of consistent quality. The purpose of this study was to prepare dexamethasone-poly(d,l-lactide-co-glycolide) (PLGA) biodegradable implants and assess implant quality within and between batches for different polymer compositions. Methods: Implants containing 20% w/w dexamethasone with 3 theoretical rates of release (fast, intermediate, and slow) were manufactured with decreasing proportion of acid-terminated PLGA (50:50) and increasing proportion of ester-terminated PLGA (50:50) in a batch process using hot-melt extrusion. The implants were manufactured without and with in-process modification of extrusion/conveyor speed in the late phase of each batch. Implant samples collected at early, middle, and late phases of each batch were analyzed for diameter, drug loading, mechanical properties (strength and toughness), and drug release. Results: With a fixed process, unlike a modified process with an increase in extrusion speed and reduction of conveyor speed in the late phase, all implant formulations tended to decrease in diameter and mechanical properties in the late phase. Drug release profiles for the intermediate and slow release compositions were similar with or without process modification, unlike the fast release composition. Addition of ester-terminated PLGA resulted in a slower drug release. When all formulations are grouped together, the implant diameter exhibited a moderate correlation with mechanical properties, but no correlation was observed with drug release. Conclusions: Within a hot-melt extrusion batch process, the dexamethasone-PLGA implant diameter and hence toughness and strength tend to decline in the latter phase. In-process adjustment of extrusion and conveyor speeds can improve batch consistency and, potentially, implant integrity or performance during or after injection. Process changes did not affect drug release for 2 of the 3 implant compositions.

Chemicals Related in the Paper:

Catalog Number Product Name Structure CAS Number Price
AP26780507-K Poly(D,L-lactide-co-glycolide) ester terminated Poly(D,L-lactide-co-glycolide) ester terminated 26780-50-7 Price
qrcode