0

Physical Stability of Highly Concentrated Injectable Drugs Solutions Used in Intensive Care Units

M Closset, J D Hecq, L Soumoy, J Simar, E Gonzalez, L Charlet, C Declave, P Gillet, L Galanti

Ann Pharm Fr. 2017 May;75(3):185-188.

PMID: 28209389

Abstract:

Background:
The intensive care department of the institution use drug solutions within higher concentration to avoid fluid overload. The purpose of the study is to prove the physical stability of different injectable drugs within high concentration (amiodarone 25mg/mL, isosorbide 0.60mg/mL, lorazepam 0.16mg/mL, noradrenalin 0.120 and 0.240mg/mL, salbutamol 0.06mg/mL and sodium valproate 12mg/mL) to ensure the patients safety.
Methods:
Five of 30 or 50mL polypropylene syringes were prepared for each solution under aseptic conditions and stored at room temperature. Immediately after the preparation (hour 0) and after 1, 4, 8, 24 and 48hours, 2mL of each solution were withdrawn from each syringe and placed in glass tubes to proceed to the stability test. All specimens were visually inspected in front of a black and of a white background and aliquots of each solution were centrifuged to proceed to microscopic inspection with a ten-fold magnification. The pH of each solution was measured with glass electrode pH-meter (Inolab level 1, WTW Weilhem, Germany with biotrode electrode, Hamilton, Bonaduz, Switzerland) and spectrophotometric measurements (Genesys 10 series, New-York, USA) were performed at three wavelengths (350, 410 and 550nm) to avoid the apparition of turbidity.
Results:
For all the drugs included in the study, there was no significant change in pH, no color change, no turbidity or opacity and no precipitation observed in the solutions during the storage at room temperature for 48hours. No microaggregates were detected by microscope neither revealed by a change of absorbance.
Conclusion:
Within these limits, the preparations of amiodarone in 5% glucose polypropylene syringes and isosorbide, lorazepam, noradrenalin, salbutamol, valproate in 0.9% sodium chloride polypropylene syringes are physically stable at room temperature for 48hours. These results allow us to consider a study of chemical stability by high-performance liquid chromatography (HPLC).