0

Radiation Shielding Parameters of Some Antioxidants Using Monte Carlo Method

Huseyin Ozan Tekin, Mesut Karahan, Turker Tekin Erguzel, Tugba Manici, Muhsin Konuk

J Biol Phys. 2018 Dec;44(4):579-590.

PMID: 29968194

Abstract:

In this paper, radiation shielding parameters such as mass attenuation coefficients and half value layer (HVL) of some antioxidants are investigated using MCNPX (version 2.4.0). The validation of the generated MCNPX simulation geometry for antioxidant structures is provided by comparing the results with standard WinXcom data for radiation mass attenuation coefficients of antioxidants. Very good agreement between WİNXCOM and MCNPX was obtained. The results from the validated geometry were used to calculate the shielding parameters of different antioxidants. The radiation attenuation properties of each antioxidant were compared with each other. The results showed that, on average, the highest and the lowest radiation mass attenuation coefficients were observed on hesperidin and delphinidin chloride, respectively. It can be concluded that Monte Carlo simulation is a strong tool and an alternate method where experimental investigations are not possible and a standard simulation setup can be used in further studies for different biological structures. It can also be concluded that the obtained results from this study are very useful for radiology and radiotherapy applications where antioxidants are frequently used.

Chemicals Related in the Paper:

Catalog Number Product Name Structure CAS Number Price
AP528530-A Delphinidin chloride Delphinidin chloride 528-53-0 Price
qrcode