0

Rapid Determination of Benzodiazepines, Zolpidem and Their Metabolites in Urine Using Direct Injection Liquid Chromatography-Tandem Mass Spectrometry

Yu-Dong Jeong, Min Kyung Kim, Sung Ill Suh, Moon Kyo In, Jin Young Kim, Ki-Jung Paeng

Forensic Sci Int. 2015 Dec;257:84-92.

PMID: 26282513

Abstract:

Benzodiazepines and zolpidem are generally prescribed as sedative, hypnotics, anxiolytics or anticonvulsants. These drugs, however, are frequently misused in drug-facilitated crime. Therefore, a rapid and simple liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of benzodiazepines, zolpidem and their metabolites in urine using deuterium labeled internal standards (IS). Urine samples (120 μL) mixed with 80 μL of the IS solution were centrifuged. An aliquot (5 μL) of the sample solution was directly injected into the LC-MS/MS system for analysis. The mobile phases consisted of water and acetonitrile containing 2mM ammonium trifluoroacetate and 0.2% acetic acid. The analytical column was a Zorbax SB-C18 (100 mm × 2.1 mm i.d., 3.5 μm, Agilent). The separation and detection of 18 analytes were achieved within 10 min. Calibration curves were linear over the concentration ranges of 0.5-20 ng/mL (zolpidem), 1.0-40 ng/mL (flurazepam and temazepam), 2.5-100 ng/mL (7-aminoclonazepam, 1-hydroxymidazolam, midazolam, flunitrazepam and alprazolam), 5.0-200 ng/mL (zolpidem phenyl-4-carboxylic acid, α-hydroxyalprazolam, oxazepam, nordiazepam, triazolam, diazepam and α-hydroxytriazolam), 10-400 ng/mL (lorazepam and desalkylflurazepam) and 10-100 ng/mL (N-desmethylflunitrazepam) with the coefficients of determination (r(2)) above 0.9971. The dilution integrity of the analytes was examined for supplementation of short linear range. Dilution precision and accuracy were tested using two, four and ten-folds dilutions and they ranged from 3.7 to 14.4% and -12.8 to 12.5%, respectively. The process efficiency for this method was 63.0-104.6%. Intra- and inter-day precisions were less than 11.8% and 9.1%, while intra- and inter-day accuracies were less than -10.0 to 8.2%, respectively. The lower limits of quantification were lower than 10 ng/mL for each analyte. The applicability of the developed method was successfully verified with human urine samples from drug users (n=21). Direct urine sample injection and optimized mobile phases were introduced for simple sample preparation and high-sensitivity with the desired separation.

Chemicals Related in the Paper:

Catalog Number Product Name Structure CAS Number Price
AP2558307 N-Desmethylflunitrazepam solution N-Desmethylflunitrazepam solution 2558-30-7 Price
AP37115438-A alpha-Hydroxyalprazolam solution alpha-Hydroxyalprazolam solution 37115-43-8 Price
AP4959175 7-Aminoclonazepam solution 7-Aminoclonazepam solution 4959-17-5 Price
qrcode