0

Ultrasound-assisted Dispersive Liquid-Liquid Microextraction Combined With Gas Chromatography-Mass Spectrometry in Negative Chemical Ionization Mode for the Determination of Polybrominated Diphenyl Ethers in Water

Qian Zhang, Tao Liang, Lili Guan

J Sep Sci. 2013 Apr;36(7):1263-9.

PMID: 23483741

Abstract:

A simple and economical method for the determination of eight polybrominated diphenyl ethers (BDE-28, 47, 99, 100,153,154,183, and 209) in water was developed. This method involves the use of ultrasound-assisted dispersive liquid-liquid microextraction combined with GC-MS in negative chemical ionization mode. Various parameters affecting the extraction efficiency, including the type and volume of extraction and dispersive solvents, salt concentration, extraction time, and ultrasonic time, were investigated. A volume of 1.0 mL of acetone (dispersive solvent) containing 10 μL tetrachloroethylene (extraction solvent) was injected into 5.0 mL of water samples and then emulsified by ultrasound for 2.0 min to produce the cloudy solution. Under the optimal condition, the enrichment factors for the eight PBDEs were varied from 845- to 1050-folds. Good linearity was observed in the range of 1.0-200 ng L(-1) for BDE-28, 47, 99, and 100; 5.0-200 ng L(-1) for BDE-153, 154, and 183; and 5.0-500 ng L(-1) for BDE-209. The RSD values were in the range of 2.5-8.4% (n = 5) and the LODs ranged from 0.40 to 2.15 ng L(-1) (S/N = 3). The developed method was applied for the determination of eight BPDEs in the river and lake water samples, and the mean recoveries at spiking levels of 5.0 and 50.0 ng L(-1) were in the range of 70.6-105.1%.

Chemicals Related in the Paper:

Catalog Number Product Name Structure CAS Number Price
AP147217796 BDE No 36 solution BDE No 36 solution 147217-79-6 Price
qrcode